Evaluation of radicular dentin remaining and risk of perforation after manual and rotary instrumentations in root canals of primary teeth: An in vitro study


Department of Pediatric and Preventive Dentistry, Navodaya Dental College and Hospital, Raichur, Karnataka, India

Date of Web Publication18-Nov-2016

Correspondence Address:
Mohammed Zameer
Galib Nagar, Raichur, Karnataka
India
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/2321-6646.194370

Rights and Permissions
  Abstract 

The aim of the study is to evaluate the efficacy of radicular dentin removal, risk of perforation, and shape of the canal on using manual and rotary instruments in primary teeth. Sixty primary teeth selected were divided into three groups; all the teeth were then embedded into resin and sectioned for examination before and after instrumentation. H-files were used for manual technique, and 2% taper and 4% taper I-Race files were used for rotary. Dentin removal was calculated using stereomicroscope-assisted digital image viewing software. Manual instrumentation has removed overall more dentin compared with 2% and 4% taper rotary instrumentation. No statistical differences were found between 2% and 4% instrumentation with respect to the amount of dentin removed. In few specimens, root perforations were observed in areas coinciding with largest root resorption. In primary teeth without significant root resorption, the use of nickel-titanium-rotary files with 2% and 4% taper up to size 30 revealed to be safe and had prepared the root canals with greater conservation of tooth structure than manual instrumentation. However, 4% taper instrumentation had an additional advantage of providing more funnel-shaped canal desired for ideal compaction of obturating material.

Keywords: H-files, I-Race, Manual instrumentation, Root perforation, Rotary instrumentation, 2% and 4% taper


How to cite this article:
Zameer M. Evaluation of radicular dentin remaining and risk of perforation after manual and rotary instrumentations in root canals of primary teeth: An in vitro study. J Pediatr Dent 2016;4:57-65

How to cite this URL:
Zameer M. Evaluation of radicular dentin remaining and risk of perforation after manual and rotary instrumentations in root canals of primary teeth: An in vitro study. J Pediatr Dent [serial online] 2016 [cited 2017 Aug 22];4:57-65. Available from: http://www.jpediatrdent.org/text.asp?2016/4/3/57/194370


  Introduction Top


In pediatric dentistry, pulpectomy is a preferred root canal procedure for pulp tissue that is irreversibly inflamed or necrotic. The anatomic and physiologic features of primary teeth can present challenges to the clinician wishing to undertake pulpectomy. However, with knowledge of these features and how they may impact on clinical technique, pulpectomy can be a clinically successful option.[1]

Root canal preparation techniques using manual instruments have found to be time-consuming and may lead to iatrogenic errors such as ledging, zipping, canal transportation, and apical blockage. To overcome this, much attention has been directed toward root canal preparation using nickel-titanium (NiTi)-rotary instruments. The flexibility and the instrument design of NiTi-rotary files allow it to closely follow the original root canal path. Studies have consistently shown acceptable cleaning ability of NiTi instruments and considered to be more effective way to debride the uneven walls in primary teeth.[2],[3]

However, evaluation of the amount of dentin removal from the root canals of primary teeth upon using manual and rotary endodontic instruments has not been much investigated yet. Therefore, the present study was opted to evaluate the amount of dentin removal and the risk of perforation when root canals were instrumented using H-file and I-Race rotary files.


  Materials and methods Top


The present study was conducted in the Department of Pediatric and Preventive Dentistry at Navodaya Dental College and Hospital, Raichur. Evaluation of the study was done by the Ethical Committee of the Institute, and ethical approval was obtained before the study.

Sample size estimation

The sample size was estimated using the given formula:

n = (Zα/2 + Zβ)2 × 2 × σ2/d2

n = (1.96 + 1.282)2 × 2 × (0.09)2/(0.08)2 = 27 ≈ 28 (final sample size)

The total sample of this study comprised sixty human primary teeth extracted for reasons not related to the study. Mainly, teeth were donated by patients from public health-care services where tooth extraction is the only treatment available for teeth with compromised pulp and periradicular tissues. Others were extracted because they were unrestorable or taken up for treatment through serial extraction.

Inclusion criteria



  1. Teeth with minimal apical resorption with the presence of at least two-third remaining root structure
  2. Teeth with the absence of visual perforating resorption.


Exclusion criteria



  1. Teeth with calcified root canal
  2. Teeth with the presence of any visual perforation on the roots.


Study design

Based on the selection criteria, sixty primary teeth were selected and stored in formalin. Ultrasonic scaler was used to clean soft-tissue debris or calculus attached to the teeth. Teeth were divided into three groups (n = 20): Group A - 4% taper rotary, Group B - 2% taper rotary, Group C - manual. The real tooth length was established by visual observation, with 19 mm k-file size 8 or 10 until it could be seen at major apical foramen. Buccolingual and mesiodistal radiographs were taken. The working length corresponded to the real tooth length [Figure 1]. An accurate simplified Bramante muffle system[4],[5] was used for the specimens. A rectangular plaster model with orientation grooves at every 2 mm was prepared. Impression was made with elastomeric material to obtain a mold opened at one end. The tooth with screws was stabilized on a modeling wax such that tooth and the screws are parallel to each other. Resin was poured into the mold, and the frame comprises tooth and screws was embedded into resin. Embedment was carried out with the tooth crown protruding to the level of cementoenamel junction, and the roots were placed parallel to the long axis of mold. After the resin had been set, screws were removed from the mold. Tooth-resin block was transversely sectioned using micromotor, with 0.25 mm thick diamond disc [Figure 2]. Following the orientation grooves at every 2 mm, the most three sections were obtained from each tooth-resin block and were labeled to indicate the section within each sample.
Figure 1: (a and b) Preinstrumentation radiographs, (c) real-tooth length determination, (d and e) working length corresponding to the real tooth length

Click here to view
Figure 2: (a) A rectangular block with orientation grooves, (b) preparation of mold using the elastomeric impression material, (c-e) embedment of tooth with screws for building up tooth-resin block, (f) tooth-resin block with orientation grooves for sectioning, (g-i) three sections of the tooth-resin blocks ready for imaging

Click here to view


Image recording of the sections before instrumentation was performed under a Nikon SM225 model P2-Firl stereomicroscope attached digital camera Nikon Digital Sight-Ds-Fi2-K18944, Japan [Figure 3]. Tooth surface positioning and magnification (×0.63) were standardized for all the sections.
Figure 3: (a-c) Preinstrumentation recorded images under stereomicroscope, (d-f) postinstrumentation recorded images under stereomicroscope, (g and h) comparison of shape of the canal upon using rotary and manual files, (i) stereomicroscope

Click here to view


Measurement of dentin thickness in different root wall was taken from the external limit of the root canal to the surface of the root. In each wall, the thinnest area between the canal wall and the external root surface was recorded. The total sample (n = 60) was divided into three groups; each group was equally divided to have the same type of teeth and the same number of root canals per group. Teeth were thus randomly divided into two subgroups (n = 10 in each group), maxillary molars and mandibular molars. At this time, the groups were defined and sections were repositioned for instrumentation using manual and rotary files. Protocol for instrumentation was standardized: manual (H-files) and rotary (I-Race files both 2% and 4% taper) up to size 30. All canals in both groups were copiously irrigated with 2 ml of 3% sodium hypochlorite and saline before preparation and after instrumentation using disposable syringe. Totally, 8 sets of rotary instruments were used (4 sets of 2% taper and 4 sets of 4% taper). Each instrument was used for preparation of five specimens. Totally, 4 sets of H-files were used for manual instrumentation. Each set of manual H-files comprises 4 instruments of size from 15 to 30. Each set of rotary comprises three instruments: 6% taper size 30, followed by size 25-30 for each taper group. Instrument movement followed for manual files was clockwise half-turn followed by a similar counter-clockwise motion and withdrawal. Each instrument performed nearly 15 circumferential filing movements on the root canal walls. The rotary instrumentation (n = 20 for 2% taper, n = 20 for 4% taper) was performed with I-Race system. Preparation was performed with 21 mm NiTi instruments using step-back technique following to the manufacturer instruction. After completion of shaping, sections were separated and images were recorded and analyzed using image viewing software [Figure 3]. Data obtained were subjected to statistical analysis.

Statistical analysis

Descriptive statistics such as mean, standard deviation (SD), and percentage were used. Comparison between manual and rotary was done using unpaired t-test for normal data and Mann–Whitney test for nonnormal data. Comparison between before and after instrumentation was done using paired t-test. Comparison between groups of categorical data was done using Chi-square test. A P < 0.05 was considered statistically significant.


  Results Top


Instrument failure

There were no H-file or I-Race rotary instrument fractures during preparation.

Radicular dentin thickness

The mean and SD of root canal areas before and after instrumentation and the amount of dentin removed according to the type of instrumentation, root third, and different dental groups are summarized in [Table 1][Table 2][Table 3].
Table 1: Root canal areas (mm2) before and after instrumentation and amount of dentin removed according to the type of instrumentation and root third in the maxillary and mandibular molars teeth (mean±standard deviation)


Click here to view
Table 2: Root canal areas (mm2) before and after instrumentation and amount of dentin removed according to the type of instrumentation and root third in the maxillary molars (mean±standard deviation)


Click here to view
Table 3: Root canal areas (mm2) before and after instrumentation and amount of dentin removed according to the type of instrumentation and root third in the mandibular first and second molars (mean±standard deviation)


Click here to view


Total sample size

Manual instrumentation removed larger amount of dentin at the coronal and middle third compared with rotary instrumentation (P < 0.05) at the same root thirds in all roots and dental groups, except to the apical third (P > 0.05)

Comparison between 2% taper and 4% taper rotary instrumentation revealed overall no statistically significant difference (P > 0.05) with respect to the amount of dentin removed.

Maxillary teeth

Manual instrumentation has removed a larger amount of dentin at the coronal third of mesiobuccal, distobuccal, and palatal roots of the maxillary molars compared with rotary instrumentation at the same root third (P < 0.05)

Comparison between 2% taper and 4% taper rotary instrumentations revealed overall no statistically significant difference (P > 0.05) with respect to the amount of dentin removed in all roots of maxillary molars, except the coronal and middle third of the distobuccal root (P < 0.05).

For standardization, the root canals of the mandibular first and second molars were combined with respect to the roots to which they belonged and were named as mesial and distal canals.

Mandibular teeth

Comparison between manual and rotary instrumentation did not show any statistically significant difference (P > 0.05) with respect to the amount of dentin removal in all the roots of mandibular molars, except the coronal third of the mesial root (P < 0.05)

Comparison between 2% taper and 4% taper rotary instrumentations revealed no statistically significant difference (P > 0.05) with respect to the amount of dentin removed in all the roots of mandibular molars, except the coronal third of the distal root of mandibular molars.

Root perforations

Results regarding root perforation comparing type of instrumentation, dental group, roots, and root thirds are summarized in [Table 4] and [Table 5]. [Table 4] indicates no statistically significant differences between groups according to Chi-squared test (P > 0.05).
Table 4: Number and percentage of perforations according to the type of instrumentation, group of teeth, and root


Click here to view
Table 5: Number of root perforations for the different groups of teeth, roots, and thirds


Click here to view


Canal shape

Qualitative visual analysis of images revealed achievement of more regular instrumentation with rotary technique [Figure 3g] whereas manual instrumentation usually provided more irregular shaping [Figure 3h].


  Discussion Top


Initially, root canal instruments were produced of carbon steel, stainless steel alloys, and now, the advancement is toward the use of NiTi files. These instruments have shown an enhanced flexibility and superior resistance to torsion fracture and reduced procedural errors.[6]Curvatures and irregularities of root canal walls of primary teeth have shown to be cleaned efficiently with NiTi instruments similar to the manual filing.[3] Among several methodologies developed to evaluate root canal shaping, Bramante et al.[4] method allows a comparison of the root canal before and after instrumentation and also provides a three-dimensional view of the preparation throughout the root canal length. In our study, we have followed a simplified Bramante muffle system.

It is generally recommended to maintain the original anatomic shape of the root canal to preserve maximum dentin thickness. Meanwhile, it is also considered to effectively enlarge the root canal, with the objective to remove its organic and inorganic contents.[7],[8] However, primary teeth discourage gross enlargements of the canals due to its ribbon-shaped morphology with a narrow mesiodistal width as compared to their buccolingual dimensions. Based on the recommendations,[9],[10] instrumentation till size 30 has considered to be safe in providing successful results. Therefore, in the present study, apical diameter prepared up to size 30 in both manual and rotary groups.

In our study, manual root canal instrumentation was done using H-files. The advantages of using these files as reported are more positive rake angle and a blade with cutting rather than scraping angle. Furthermore, it has a unique cutting fashion that allows cutting only during pulling stroke which prevents pushing infected material through the apices.[11],[12],[13],[14],[15]

Barr et al.[2] advocated that instrumentation in primary teeth using rotary files is faster than hand files. It is not necessary to use a crown-down technique in primary teeth since the dentin cuts more easily in primary teeth than in permanent teeth. Meanwhile, care must be taken not to over instrument as perforations can easily occur in the thin dentinal walls. The manufacturer of I-Race rotary files has suggested two step-back and one crown-down operator sequence.[16] The step-back technique starts with coronal flaring using 6% taper size 30 file. (After coronal flaring) Subsequently, instrumentation for 2% taper files from size 25 to 40 and for 4% taper files from size 25 to 35 is recommended(by the manufacturer). Baumann[17] recommended instrumentation using Race rotary files at speed between 300 rpm and 600 rpm, with light apical pressure in a “pumping-pecking” motion. The protocol of instrumentation for the present study was followed as recommended by the manufacturer with I-Race rotary file of 2% and 4% taper up to size 30 in a step-back technique with pumping pecking motion.

According to the results, manual files have generated more dentin removal at coronal and middle third of all roots and groups compared with rotary files (combination of 2% and 4% taper files), except to apical third which did not show statistically significant difference. This agrees the results of the previous study.[1] The comparison of 2% taper with 4% taper I-Race rotary instrumentation revealed overall no statistically significant difference with respect to the amount of dentin removed in all roots and dental group. According to the previous studies, 4% taper rotary instrumentation is found to be efficient without undue aggressiveness in primary teeth and resulted in a smooth funnel-form preparation desired for ideal compaction of the pulpectomy paste.[2],[18] Based on our study, it can be stated that 2% and 4% taper I-Race rotary instrumentations are safe for canal preparation with regard to the amount of dentin removal.

The present study used the actual tooth length as the working length to observe the action of endodontic instruments in the presence of cementum and dentin resorption and evaluated the possibility of instrumentation at these segments. The results revealed that root perforations coincided with areas showing largest resorption, primarily affecting middle thirds and apical thirds of the root canals of the maxillary and mandibular molars. It is because the dentinal walls in these areas were thin, creating zones susceptible to perforation, which should be taken into account during treatment planning. Instrumentation using 4% rotary files revealed maximum number of perforations compared to the manual as well as 2% taper rotary files. Five perforations were in the apical third and one was in the middle third coincided with the areas showing largest resorption. 2% taper rotary instrumentation has shown the least number of perforations compared to manual and 4% taper rotary instrumentation accounted as only 3 perforations. All of them were found in the susceptible zone, i.e., the apical third.

The qualitative and visual analysis of the images in the present study revealed the achievement of more regular shape of the root canal of the primary molars after instrumentation with both 2% and 4% taper I-Race rotary files whereas manual instrumentation with H-files usually provided more irregular shaping. This is in agreement with the previous study done using rotary files Hero 642 and K-files for manual instrumentation.[1]

Limitations

The asymmetric root length of multirooted teeth did not allow the standardization of sections for evaluation of specimens. The root length in the apical third of some specimens was reduced due to resorption, leading to experimental errors.

The present study has shown no significant occurrence of root perforation upon using manual and rotary files. However, the anatomic features of primary teeth, particularly the ribbon-shaped canals with thin dentinal wall especially in the apical third, have a risk of root perforations with the use of 4% taper rotary instruments which further need evaluation and confirmation. Among all the groups of instrumentation, 2% taper rotary files revealed a safer and more conservative approach for the root canals of the primary teeth. The findings of the present study add on the development of safer and more conservative and faster protocols for the treatment of primary teeth with compromised pulp tissue.


  Conclusion Top


In primary teeth without significant root resorption, the use of NiTi-rotary files with 2% and 4% taper up to size 30 revealed to be safe and had prepared the root canals with greater conservation of tooth structure than manual instrumentation. However, 4% taper instruments can provide more funnel-shaped canal desired for ideal compaction of obturating material.

Acknowledgment

We would like to extend our heartfelt gratitude toward Prof. Prabhu Raj and Mr. Sriesh for their kind support in imaging through a stereomicroscope and the Department of Entomology, Agricultural College, Agricultural University, Raichur.

Financial support and sponsorship

Nil

Conflicts of interest

There are no conflicts of interest

 
  References Top

1.
Kummer TR, Calvo MC, Cordeiro MM, de Sousa Vieira R, de Carvalho Rocha MJ. Ex vivo study of manual and rotary instrumentation techniques in human primary teeth. Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008;105:e84-92.  Back to cited text no. 1
    
2.
Barr ES, Kleier DJ, Barr NV. Use of nickel-titanium rotary files for root canal preparation in primary teeth. Pediatr Dent 2000;22:77-8.  Back to cited text no. 2
    
3.
Silva LA, Leonardo MR, Nelson-Filho P, Tanomaru JM. Comparison of rotary and manual instrumentation techniques on cleaning capacity and instrumentation time in deciduous molars. J Dent Child (Chic) 2004;71:45-7.  Back to cited text no. 3
    
4.
Bramante CM, Berbert A, Borges RP. A methodology for evaluation of root canal instrumentation. J Endod 1987;13:243-5.  Back to cited text no. 4
    
5.
Tamse A, Pilo R. A new muffle model system to study root canal morphology and instrumentation techniques. J Endod 1998;24:540-2.  Back to cited text no. 5
    
6.
Iqbal MK, Maggiore F, Suh B, Edwards KR, Kang J, Kim S. Comparison of apical transportation in four Ni-Ti rotary instrumentation techniques. J Endod 2003;29:587-91.  Back to cited text no. 6
    
7.
Coll JA, Sadrian R. Predicting pulpectomy success and its relationship to exfoliation and succedaneous dentition. Pediatr Dent 1996;18:57-63.  Back to cited text no. 7
    
8.
Kim HC, Kim HJ, Lee CJ, Kim BM, Park JK. Versluis A, Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals. Int Endod J 2009;42:593-02.  Back to cited text no. 8
    
9.
Moskovitz M, Sammara E, Holan G. Success rate of root canal treatment in primary molars. J Dent 2005;33:41-7.  Back to cited text no. 9
    
10.
Llewelyn DR. Faculty of Dental Surgery, Royal College of Surgeons. UK National Clinical Guidelines in Paediatric Dentistry. The pulp treatment of the primary dentition. Int J Paediatr Dent 2000;10:248-52.  Back to cited text no. 10
    
11.
Machian GR, Peters DD, Lorton L. The comparative efficiency of four types of endodontic instruments. J Endod 1982;8:398-02.  Back to cited text no. 11
    
12.
Mizrahi SJ, Tucker JW, Seltzer S. A scanning electron microscopic study of the efficacy of various endodontic instruments. J Endod 1975;1:324-33.  Back to cited text no. 12
    
13.
Miserendino LJ, Brantley WA, Walia HD, Gerstein H. Cutting efficiency of endodontic hand instruments. Part 4. Comparison of hybrid and traditional instrument designs. J Endod 1988;14:451-4.  Back to cited text no. 13
    
14.
Yguel-Henry S, Vannesson H, von Stebut J. High precision, simulated cutting efficiency measurement of endodontic root canal instruments: Influence of file configuration and lubrication. J Endod 1990;16:418-22.  Back to cited text no. 14
    
15.
Eldeeb ME, Boraas JC. The effect of different files on the preparation shape of severely curved canals. Int Endod J 1985;18:1-7.  Back to cited text no. 15
    
16.
Plotino G, Grande NM, Butti A, Somma F. Modern endodontic NiTi systems: Morphological and technical characteristics. Endod Ther 2006;6:A-D.  Back to cited text no. 16
    
17.
Baumann MA. Reamer with alternating cutting edges Concept and clinical applications. Endod Topics 2005;10:176-8.  Back to cited text no. 17
    
18.
Kuo C, Wang Y, Chang H, Huang G, Lin C, Li U. Application of Ni-Ti rotary files for pulpectomy in primary molars. J Dent Sci 2006;1:10-5.  Back to cited text no. 18
    


    Figures

  [Figure 1], [Figure 2], [Figure 3]
 
 
    Tables

  [Table 1], [Table 2], [Table 3], [Table 4], [Table 5]



 

Top
 
 
  Search
 
Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
Access Statistics
Email Alert *
Add to My List *
* Registration required (free)

 
  In this article
Abstract
Introduction
Materials and me...
Results
Discussion
Conclusion
References
Article Figures
Article Tables

 Article Access Statistics
    Viewed2338    
    Printed42    
    Emailed0    
    PDF Downloaded1475    
    Comments [Add]    

Recommend this journal


[TAG2]
[TAG3]
[TAG4]